Compute all PK parameters for a single concentration-time data set
Source:R/pk.calc.all.R
pk.nca.interval.Rd
For one subject/time range, compute all available PK parameters. All the
internal options should be set by PKNCA.options()
prior to running. The
only part that changes with a call to this function is the conc
entration
and time
.
Usage
pk.nca.interval(
conc,
time,
volume,
duration.conc,
dose,
time.dose,
duration.dose,
route,
conc.group = NULL,
time.group = NULL,
volume.group = NULL,
duration.conc.group = NULL,
dose.group = NULL,
time.dose.group = NULL,
duration.dose.group = NULL,
route.group = NULL,
impute_method = NA_character_,
include_half.life = NULL,
exclude_half.life = NULL,
subject,
sparse,
interval,
options = list()
)
Arguments
- conc
Measured concentrations
- time
Time of the measurement of the concentrations
- volume, volume.group
The volume (or mass) of the concentration measurement for the current interval or all data for the group (typically for urine and fecal measurements)
- duration.conc, duration.conc.group
The duration of the concentration measurement for the current interval or all data for the group (typically for urine and fecal measurements)
- dose, dose.group
Dose amount (may be a scalar or vector) for the current interval or all data for the group
- time.dose, time.dose.group
Time of the dose for the current interval or all data for the group (must be the same length as
dose
ordose.group
)- duration.dose, duration.dose.group
The duration of the dose administration for the current interval or all data for the group (typically zero for extravascular and intravascular bolus and nonzero for intravascular infusion)
- route, route.group
The route of dosing for the current interval or all data for the group
- conc.group
All concentrations measured for the group
- time.group
Time of all concentrations measured for the group
- impute_method
The method to use for imputation as a character string
- include_half.life
An optional boolean vector of the concentration measurements to include in the half-life calculation. If given, no half-life point selection will occur.
- exclude_half.life
An optional boolean vector of the concentration measurements to exclude from the half-life calculation.
- subject
Subject identifiers (used for sparse calculations)
- sparse
Should only sparse calculations be performed (TRUE) or only dense calculations (FALSE)?
- interval
One row of an interval definition (see
check.interval.specification()
for how to define the interval.- options
List of changes to the default PKNCA options (see
PKNCA.options()
)